Simulation of Evacuated Tube Collector and Storage of Hybrid Air-conditioning System

Main Article Content

Mustafa Ahmed Abdulhussain

Abstract

The CFD transient simulation of superheating the refrigerant R410 through the heat exchange with the evacuated tube water heating system of the hybrid split air conditioner that is subjected to solar radiation of constant intensity with the contribution of fan accelerated air is performed by the ANSYS-CFX code. The comparison with experimental work showed a minimum percentage error 8% of the predicted refrigerant evaporative heat transfer with storage tank horizontal tubing. In addition, the results denoted high absorption rate for the evacuated tubes, reducing highly reversed heat transmission for the circulated water. 

Article Details

How to Cite
[1]
“Simulation of Evacuated Tube Collector and Storage of Hybrid Air-conditioning System”, JUBES, vol. 26, no. 4, pp. 158–171, Feb. 2018, Accessed: Mar. 28, 2024. [Online]. Available: https://www.journalofbabylon.com/index.php/JUBES/article/view/1074
Section
Articles

How to Cite

[1]
“Simulation of Evacuated Tube Collector and Storage of Hybrid Air-conditioning System”, JUBES, vol. 26, no. 4, pp. 158–171, Feb. 2018, Accessed: Mar. 28, 2024. [Online]. Available: https://www.journalofbabylon.com/index.php/JUBES/article/view/1074

Most read articles by the same author(s)

1 2 3 4 5 6 7 8 9 10 > >>